1. Periodically check the water filter;
2. Dust, such as the machine used to dry compressed air to carefully blow clean the machine, but must shut off the main power supply;
Failure: Before the test, the total power must be shut down due to the inside of the machinethousands of volts first 10,000 volts.
Phenomena 1: common red light (overload light)
Cause:
A) lower mold insulation damage;
B) the work material, the vibration drum or the upper and lower mold dirt, dust, moisture need to clean up bad bit of;
C) the level of the upper and lower mold; no insulation) the upper and lower mold, directly touch each other;
E) input power is too high;
F) vacuum tube damaged or loose;
G) had power to protect the electronic boards is damaged, over-current protection plate that is that one of the three appliances;
H) with the modem is too large, the output is too high;
I) work matter too much, to exceed the rated output with the machine;
J) temperature part of the fault;
K) damage to the high voltage capacitor; damage to
L) insulated column (on the template).
Phenomenon 2: high-week output, the total power supply is disconnected or burning fuse.
Cause:
A) vacuum tube failure
B) high-voltage rectifier transformer fault
C) board failure
D) three-phase magnetic switch damage
E) high voltage transmission line short-impaired
F) electric hot plate failure
Phenomenon 3: Not output
Cause:
A) switch is poor contact
B) line fault
C) vacuum tube failure is bad
Phenomenon 4:workload
Cause:
A) to adjust adverse;
B) mold problem
C) pieces of plastic (work objects) problem
D) insulation thick, the insulation is too high
Attention to: the encounter mold, ground copper mold under pressure to suppress made up disk, round copper slightly deformed can. If this grounding copper did not adjust well, this machinery will not be able to work steadily. This ground when the switch to a different height of the mold copper need to be adjusted once.